1735
Getting Started
Measurement
If you select this measuring mode you will see the following display:
21
4 5
Hold/Run "freezes" the actual value and the measurement is stopped or started
again.
Save
Save/Enter yields a screenshot and stores the picture of the display in the
memory location subsequently shown.
Logging Function
Record/Measure starts the logging function or you can get back into the
measuring mode. Before the start, the maximum logging time is indicated and
you can change this value with Esc followed by entering using CURSOR.
Changes in the averaging time cause corresponding changes in the logging
time of the measurement (double averaging time = double logging time).
When the logger graphics reach the screen margin during recording, a picture
of this screen is saved.
18
Use this switch to get the following values:
- minimum of values
- maximum of values and
- frequency or neutral-conductor current
edx024.bmp