► Connect the hydraulic tester in the direction indicated on the rating plate in
order to achieve a higher level of measuring accuracy.
► Connect the hydraulic tester at a point on the hydraulic circuit which is
exposed to as little vibration as possible so that measurement results are
not falsified.
► Install a 25 micron filter in the hydraulic circuit upstream from the hydraulic
tester to prevent impurities.
► The diameters of the inlet and outlet connections should be similar to the
diameter of the hydraulic tester connections to prevent Venturi or constric-
tion effects. Smaller diameters lead to overheating.
► Due to the integrated flow straighteners, you can reduce the normal rec-
ommended length of the straight hose section of 10 times the hose diam-
eter to 8 times the hose diameter.
► The hydraulic tester can be assembled in any orientation.