User
The CoDeSys controller type CPX−CEC−C1 is intended for
use only in CPX terminals. The limit values specified in the
section Technical specifications" must be observed here.
Detailed information can be found in the description for
the CPX−CEC−C1 (P.BE−CPX−CEC−..) as well as in the CPX
system description (P.BE−CPX−SYS−..).
Warning
S Switch off the power supply before connecting or
disconnecting plug connectors (otherwise this could
lead to functional damage).
S Use only power units which guarantee reliable
electrical isolation of the operating voltage as per
IEC/DIN EN 60204−1. Observe also the general
requirements for PELV power circuits as per
IEC/DIN EN 60204−1.
S Connect an earth conductor of sufficient cross−
sectional area to the connection on the CPX terminal
marked with the earth symbol.
S The CPX−CEC−C1 contains electrostatically sensitive
devices. Therefore, do not touch any contacts. Ob
serve the handling specifications for electrostatically
sensitive devices.
Note
Only commission a CPX terminal if it has been has been
fitted and wired completely.
Festo P.BE−K−CPX−CEC 0907NH English
instructionsEnglish