Maintenance
l WARNING!
Danger due to dust
▶ Switch off the vacuum cleaner and remove the batteries
before every service.
▶ Wear suitable personal protective equipment.
▶ Clean the vacuum cleaner before dismantling.
▶ Disassembly must be carried out before carrying out locally
filtered forced ventilation.
▶ Clean the maintenance area after the work.
7.1 Precautions for class M vacuum cleaners
The exterior of the vacuum cleaner should be cleaned by vacuum-
ing and wiped clean or treated with sealants before removing it from
the hazardous area. All vacuum cleaner parts must be considered
contaminated when they are removed from the hazardous area and
appropriate precautions must be taken to prevent dust dispersion.
Contaminated objects
When carrying out service or repairs, any contaminated objects
which cannot be cleaned satisfactorily must be disposed of. These
objects must be disposed of in impermeable bags in compliance
with applicable waste disposal regulations.

7.2 Changing the motor protection filter

If the motor protection filter is dirty, this indicates defective filter
cassettes.
▶ Replace the pleated filter cassettes.
▶ Replace the motor protection filter or wash the motor protection
filter under running water, dry it and reinsert it.
7.3 Testing the effectiveness of the vacuum
cleaner
At least once a year, the manufacturer or a trained person should
carry out an inspection of the dust technology to check for damage
to the filter, the seal of the vacuum cleaner and the function of the
inspection device, among other things.
There must be a sufficient air exchange rate L in the room when the
exhaust air returns to the room. Observe national regulations.
If the suction power of the vacuum cleaner decreases and even
cleaning the pleated filter cassettes no longer increases the suction
power (provided that the container is empty and the non-woven
filter bag has been replaced), the pleated filter cassettes must be
replaced (see chKap. 5.6 „Changing the pleated filter" on page
31).
8
Cleaning
l WARNING!
Danger due to improper cleaning
Equipment that is not properly maintained poses a danger to
the user.
▶ When using in food processing facilities: Clean and disinfect
the vacuum cleaner immediately after use to prevent
contamination.
▶ Do not use flammable cleaning agents.
▶ Do not clean with steam jet equipment or high-pressure
cleaners.
▶ Do not clean the filter cassettes with compressed air.
Acid, acetone and solvents can damage vacuum cleaner parts.
▶ Clean containers and accessories with water.
▶ Wipe the top with a damp cloth.
▶ Allow the containers and accessories to dry.
▶ Clean the battery contacts regularly.