Extracting dust when using power tools
See Fig. F.
Use socket on vacuum cleaners with automatic switch on/off (switch position A) to connect electrical tools. The
vacuum cleaner is switched on and off by the electrical tool. In switch position 0, the socket can be used as an
extension cable, e.g. for a light.
Connection value: Vacuum cleaner + electrical tool = max. 16 A (value depends on the country version, pay
attention to technical data).
WARNING!
The socket on the vacuum cleaner is always live!
Risk of injury due to electrical tool automatically starting up.
1. Before plugging in: Switch off electrical tool.
r Submersible pump is removed (see "Removing the submersible pump").
r Filter cartridge FPP 3600 is inserted.
r Filter bag is inserted in the container.
r Power tool is switched off.
r Vacuum cleaner is switched off.
1. Connect suction hose to power tool and vacuum cleaner (F2,3).
2. Connect power tool to the socket on the vacuum cleaner (F4).
3. Set switch to position A (F5).
4. Switch on the power tool (F6).
9 The vacuum cleaner is switched on by the power tool.
Castors with brake
See Fig. G.
1. Apply the brake with your foot.
9 The vacuum cleaner is prevented from rolling away.

Blowing function

See Fig. H.
Only use the blowing function for cleaning and drying machines and appliances.

Emptying the container

See Fig. I.
1. Open latches.
2. Remove cover and suction hose from the container.
3. Empty the container.
or
Tip the container in the frame
or
Lift container out of the frame
Depending on model
1)
.
1)
and empty.