Carel humiSteam Wellness Manual Del Usuario página 17

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

in each band.
The start time and the set point are set for each time band. The time band end time is represented by the start of
the next time band. The ON/OFF time bands can be set at the same time as the set point time bands, allowing
interaction between the two functions.
To set one of the fi elds:
-
press the "ENTER" button repeatedly until moving the cursor to the required fi eld;
-
press the "UP" or "DOWN" button to change the value of the fi eld;
-
press "ENTER" to confi rm.
1. From the main screen, press the "PRG" button;
2. input the password 77 by the "UP" and "DOWN" keys and press "ENTER" to confi rm;
3. using the "UP" or "DOWN" keys, select the SANIFICATON manu and press "ENTER" to confi rm
The other available menus are described in +030220571 user manual.
4.1 Sanifi cation
The unit features a cabin sanifi cation cycle using an external pump that injects disinfectant through the steam hose.
The sanifi cation cycle has two programmable operating modes:
- Manual
- Automatic
In manual mode the cycle is activated from the quick menu.
In automatic mode, available only if the On / Off time bands are enabled, the cycle is activated at the "end of the
day", that is, at the end of the last programmed On cycle within the 24 hours.
The sanifi cation cycle is made up of two distinct phases, during which the following can be set:
-
inlet fan status
-
exhaust fan status
-
sanifi cation pump status
-
percentage of steam production
During the sanifi cation cycle the main screen will display the following message, fl ashing:
+040000010 rel. 1.0 - 03.01.2007
4. SANIFICATION CYCLE
(If present)
(If present)
(If present)
SaniÞ c.
Make sure that the cabin has been evacuated when starting the
sanifi cation cycle.
WARNING!
9
english

Publicidad

Tabla de contenido
loading

Tabla de contenido