1.1 Main screen

The main screen, illustrated in the fi gure, shows the temperature read and the set point set, the name of the
essence or essence activated and the operating icon (see Table1.a). The bars to the sides indicate the function of
the corresponding button (see Figure 1.a). This screen is displayed whenever the unit is started and during normal
operation.
Pressing the "ALARM" button
displays the list of active alarms
Pressing the "PRG" button
accesses the main menu
Meaning of the icons
Icon
Meaning
Steam production not active. The unit is off, disabled or
shutdown
Steam production in progress. The unit is producing steam
Cabin light on
If visible indicates that the unit is working with time bands
FanAt least one of the two available fans is operating
Exhaust fan on
Inlet fan on
For the meaning of the requirements, see manual +030220571 - Hardware maintenance.
+040000010 rel. 1.0 - 03.01.2007
1. CHANGE OF SET POINT
Fig. 1.a
Pressing the "UP" button
increases the set point by 0.1°C
Pressing the "ENTER" button
accesse the quick menu
Pressing the "DOWN" button
decreases the set point by 0.1°C
Requirements
-
Remote ON/OFF closed
Temperature < set point
No active alarms
Light management activated
Time bands activated
At least one fan activated
Exhaust fan activated
Inlet fan activated
5
Tab. 1.a