3
Notes on fitting and installation
Warning
Before carrying out fitting, installation and/or
maintenance work, always switch off the power supply.
Warning
If an axis is fitted in a sloping or vertical position, the
work load may slide down.
S Check whether additional external safety measures are
necessary (e.g. toothed latches or moveable bolts).
S Use the motor unit preferably with self−locking
spindle drives.
This will prevent the work load from dropping suddenly
in the event of a power cut.
MTR−DCI−...
Rated
1) 2)
voltage
2)
Rated current
2)
Peak current
2) 3)
Power unit
2)
External fuse
1) The tolerance must be observed directly at the voltage connection.
2) Specifications for the load voltage supply 3) Recommended
4) with separate logic voltage supply: logic 24 V DC ±10%.
Festo P.BE−K−MTR−DCI 0703b English
32
42
24 V DC ±10%
0.73 A
2 A
2.1 A
3.8 A
24 V DC/3 A
24 V DC/6 A
5 A slow−
7 A slow−
blowing
blowing
52
62
48 V DC
+5/−10%
5 A
6.19 A
7.7 A
20 A
24VDC/10A
48 V DC/20 A
10 A slow−
25 A slow−
blowing
blowing
4)