6

Commissioning

Recommendation
8 007 716/KA 06/31-03-00
Commissioning
The device is switched on by applying the supply voltage to
both the sender and the receiver. The device is ready for
operation after 2 s. The function of the LEDs is explained in
chapter 3.4.1.
See FGS Technical Description for more detailed information.
6.1

Alignment

When the FGS has been mounted and electrically connected,
the sender and receiver must be aligned with each other.
This alignment is best made with the alignment aid AR 60 (part
no. 1 015 741, adapter: 4 030 282).
The red and green LEDs on the receiver assist in aligning the
units to each other:
Ensure the sender and receiver units are mounted at the
same horizontal level, then, swivel the units until the green
condition is obtained. The correct setting is at the centre of
the green condition limits. Tighten all fixing screws.
© SICK AG • Safety Systems • Germany • All rights reserved