Descargar Imprimir esta página

Technical Specifications - SICK GL6V Instrucciones De Operación

Ocultar thumbs Ver también para GL6V:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 56
10

Technical specifications

Sensing range (with reflector PL80A)
Sensing range max. (with reflector PL80A)
Light spot diameter/distance
Supply voltage V
S
Output current I
max.
Max. switching frequency
Max. response time
Enclosure rating
Protection class
Circuit protection
Ambient operating temperature
Limit value; operation in short-circuit protection mains max. 8 A; residual ripple max. 5 V
1)
2)
With light / dark ratio 1:1
3)
Signal transit time with resistive load
4)
IP68: according to EN 60529 (water depth of 1 m / 24 h).
IP69K: according to ISO 20653:2013-03.
5)
Reference voltage DC 50 V
6)
A = U
-connections reverse polarity protected
V
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
8021851 | SICK
Subject to change without notice
TECHNICAL SPECIFICATIONS
GL6-xxxxxV
0.07 ... 5.0 m
0.03 ... 6.0 m
8 mm / 350 mm
DC 10 ... 30 V
1)
100 mA
1,000 Hz
2)
<0.625 ms
3)
IP 67, IP 68, IP 69 K
III
5)
A, B, D
6)
-25 °C ... + 55 °C
ss
10
4)
11

Publicidad

loading