To enter Setup mode, press the SETUP button once.
Doing so will clear all three readouts and cause the
word SETUP to begin flashing on the top line of the
LCD. SETUP will continue to flash until all steps of
the setup procedure have been completed.
Note: It's important to understand that you must
complete the entire 7-step Setup procedure
shown above each time you initiate it. If you
power off the thermometer during an interim
step, none of your settings or changes will be
saved.
Step 1 of the procedure enables you to configure the
thermometer for the type of thermocouple to be
used. DT62 users: You cannot plug two different
types of thermocouple into the T1 and T2 jacks on
the top of the unit (Fig. 1, Callouts 2 and 3). You must
use two probes of the same type.
By default, the DT61 and DT62 are configured to
work with "K" type thermocouples. To use a "J", "T"
or "E" thermocouple, press the
the correct letter replaces K at the right of TYPE on
the left side of the LCD.
On the DT61, you can also change the thermocouple
type by pressing the TC TYPE button repeatedly with
the thermometer in real-time measurement mode.
After you complete Step 1, press the SETUP button
again to initiate Step 2. During this step, the word
OFFSET appears on the top line of the LCD, with the
term T1 in the upper left corner.
Step 2 of the procedure enables you to set the
amount of temperature compensation (offset) to be
applied to the Channel 1 (T1) thermocouple. Pressing
the
button applies a positive offset, and pressing
the
button applies a negative offset. Each press of
either button adds 0.1°C of compensation to the
amount shown on the primary readout. The
8
or
button until