*P516-909*
P516-909
L9000 Series Lock with Indicator Sectional Trim
Indicator trim is available for either the inside or outside of the door on allowable functions.
Non-indicator trim is furnished on the opposite side of the door.
The L9000 lock with indicator is not intended for exterior door applications.
For retrofit, see page 7.
Thumb
Cylinder
turn
Non-indicator thumb turn or cylinder
furnished on inside of door when outside
of door is ordered with indicator trim,
depending on configuration.
Check the door preparation dimensions with the template included in the package.
1
IMPORTANT! Check lock handing before installation
To change handing:
1. Pull out the latch
and rotate 180°.
2. Remove the lock
handing screw
from one side of
the chassis and
install it on the
opposite side.
The lock handing
screw should
always be on the
interior side of
he door.
L9000 Lock with Indicator
Tools
Inside cylinder indicator with outside cylinder
non-indicator sectional trim shown
Pull
Rotate
180°
Handing
screw
2
Prepare the door for indicator trim
Two Z\," pilot holes are required to mount the indicator.
ONLY ONE SIDE OF THE DOOR – THE INDICATOR SIDE –
REQUIRES THIS PREPARATION. Use the template included in
the package to mark the location of the pilot holes before drilling.
¹⁄₈" pilot
hole x 2
Inside of door
Installation Instructions
OR
OR
¹⁄₈" pilot
hole x 2
Outside of door