Electrical Data; Operating Conditions; General; Applications - DAB ACTIVE EC Serie Instrucciones Para La Instalación Y El Mantenimiento

Ocultar thumbs Ver también para ACTIVE EC Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 65
Active System
7.1 Dip-Switch regulation
pressure vales in the Pressure and flow
switch function.
9.1 Dip-Switch regulation
pressure values
ENGLISH
Page

1. GENERAL

25
25
25
25
25
Installation, electrical connection and commissioning must
25
be carried out by skilled personnel in compliance with the
26
general and local safety regulations in force in the country
26
of installation of the product. Failure to comply with these
26
instructions not only causes risk to personal safety and
27
damage to the equipment, but invalidates every right to
27
assistance under guarantee.
27
The appliance is not intendend for use by persons
(including children) with reduced physical, sensory or
28
mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction
28
concerning use of the appliance by a person responsable
29
for their safety. Children should be supervised to ensure
30
that they do not play with the appliance.
31

1.1 Applications

ACTIVE is a compact pressure boosting system composed
31
of a pump, a motor and a built-in control unit, which can
31
also be installed outside.
It is used in particular for increasing the pressure in
31
storage tanks and for water supply:
- in domestic pressure boosting systems,
- for small farming and gardening applications,
31
- for industrial services and systems,
31
- for washing systems and hobby applications.
The pump can be used for pumping rainwater, drinking
water and non drinking water.
31

2. PUMPED FLUIDS

31
The machine has been designed and built for pumping
32
water, free from explosive substances and solid particles
32
or fibres, with a density of 1000 kg/m³ and a kinematic
32
viscosity of 1 mm²/s, and chemically non-aggressive
32
liquids.
Small sand impurities of 5-10 gr./m³ - Ø 1 mm are
32
accepted.

3. TECHNICAL DATA

32
32

3.1 Electrical data

- Supply voltage:
32
- Max. current:
32
- Degree of protection:
- Insulation class:
32
- Power cable:
32
33

3.2 Operating conditions

34
- Range of operation:
34
- Head up - Hmax (m):
34
- Liquid temperature:
34
34
- Environment temperature:
34
- Storage temperature:
- Maximum working pressure:
34
- Relative humidity in air:
35
- Connections:
- Noise level:
36
217
25
Read this documentation
carefully before installation.
1x220-240V 50/60Hz
6,5 A
IP55 Active - IP44 Motor
F
1,5 mt H05 RN-F
with/without plug
0,3 ÷ 8,4 m³/h
page 218
0 ÷ 35°C domestic use
(EN 60335-2-41)
0 ÷ 40°C
-10 ÷ 40°C
8 bar (800 Kpa)
Max. 95%
1" GAS / NPT
Directive EC 89/392/EEC

Publicidad