Descargar Imprimir esta página

Festo CMMS−AS Manual De Instrucciones página 2

Ocultar thumbs Ver también para CMMS−AS:

Publicidad

Motor controller
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
This product is listed by Underwriters Laboratories Inc.
(UL). Representative samples of this product have been
evaluated by UL and meet applicable UL requirements.
UL approval information
Product category code
NMMS (USA)
File number
E331130
Considered standards
UL 508C, 17th Edition
UL mark
Product category
Ind. Cont. Eq.
(Industrial Control Equipment)
Control number
1UD1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fitting and commissioning to be carried out by qualified
personnel only in accordance with the operating in
structions.
Such qualified personnel must have several years of
training and experience in installing and commissioning
electrical and pneumatic industrial control systems.
· Please observe the applicable safety requirements
and standards.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Internal Overload Protection
· Internal Motor Overload Protection level is adjusta
ble.
For information on 'Setting the current limit values' see
'Commissioning CMMS−AS / CMMD−AS' (type P.BE−
CMMS−AS−.. or P.BE−CMMD−AS−..).
Extracts )* from the UL report:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Functional Safety
UL does not evaluated Functional Safety for Power Con
version Equipment, Series CMMS−AS or CMMD−AS or
equivalent.
Differing or additional technical specifications
Electrical Ratings
CMMS−AS
Power supply V
95 ... 250 V
,
rated
AC
50/60 Hz, 1 phase
Current
5
4 A
Rated current per phase
1 x 4 A
Note
(0 ... Input Voltage,
3 phase, 0 ... 1000 Hz)
Maximum Surrounding
40 °C
Air Temperature
Control Supply (X9)
24 Vdc, 1 A
Relay output
(X3)
60 Vac, 0.5 A (Resi
stive)
30 Vdc, 2 A (General
Purpose, Resistive)
Note
Motor Brake output
(X6)
24 Vdc, 1.0 A
(Pilot Duty)
Enclosure
IP 20 (according IEC 60 529)
To be used in a Pollution Degree 2 envi
ronment only.
Internal resistor breaking power
CMMS−AS
Continuour Power
5.5 W
Impulse Power
630 W
External resistor breaking power
CMMS−AS
Brake Resistor Min.
100
Impulse PowerContinu
100 W
ous Power
Impulse Power
1600 W
Required Markings
Integral solid state short circuit protection does not pro
vide branch circuit protection. Branch circuit protection
must be provided in accordance with the Manufacturer
Instructions, National Electrical Code and any additional
local codes.
If Pin 2 in Terminal X3 in CMMS−AS unit, in Terminal X3.1
and X3.2 in CMMD−AS unit is externally sourced, than
shall be protected by external, UL recognized according
UL248−12 fuse, rated min. 24Vdc / 4Adc.
Note
CMMS−AS:
Suitable for use on a circuit capable of delivering not
more than 5000 rms symmetrical amperes, 250 volts ma
ximum.
CMMD−AS:
Suitable for use on a circuit capable of delivering not
more than 5000 rms symmetrical amperes, 250 volts ma
ximum. When protected by RK5 Class Fuses rated 15A,
CMMD−AS
min. 250V.
95 ... 250 V
,
AC
50/60 Hz, 1 phase
10
8 A
)* taken over essentially without important changes
2 x 4 A
Wiring terminals
Connector
40 °C
24 Vdc, 3.6 A
[X1]
control wiring
(X3.1, X3.2)
[X2], [X10]
signal wiring,
60 Vac, 0.5 A (Resi
encoder supply wiring
stive)
30 Vdc, 2 A (General
[X3]
Safe stop
Purpose, Resistive)
[X5]
RS232/RS485 interface wiring
(X6.1, X6.2)
24 Vdc, 1.0 A
[X6]
motor supply wiring, motor
temp. sensor and brake (option)
[X9]
power supply wiring,
24 V DC supply wiring,
external braking resistor wiring
CMMD−AS
2 x 5.5 W
2 x 630 W
CMMD−AS
50
200 W
3200 W
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tightening
Torque
[pount inch]
(D−SUB)
(D−SUB)
min.: 1.95
max.: 2.21
(D−SUB)
min. 4.43
max.: 5.31
en