Troubleshooting: Check Valve Replacement - Bradley Navigator S19-2010 Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

S19-2010 Series

Troubleshooting: Check Valve Replacement

A
Remove the (4) screws that join the faucet
and eyewash sections together. Separate the
sections and set the faucet half aside.
B
Remove the (2) O-rings, and then use a
needle nose pliers to remove the first set of
check valves and discard.
Remove the (2) spacers from the middle of
C
the water passage. Use Extraction Tool (130-
150) or a tool with a small hook tip to remove
the last set of check valves and discard.
D
Visually inspect the eyewash water passage
for any debris. Flush water from the eyewash
outlet to clean the water passage.
Flush water from the eyewash outlet to clean
E
the water passage. Install the new check
valves. Contact your Bradley representative
to order Check Valve Kit (S65-502).
F
Visually inspect the faucet water passage for
any debris. Flush water from the faucet outlet
to clean the water passage.
10
1/20/2020
Flushing
Flushing
Bradley • 215-1873 Rev. B: ECO 20-09-002