4.2 Technical data

Fig. 4
Tab. 1
Cooling capacity (H2O) Q = 1 l/min
Cooling capacity (BTC-15*) Q = 1 l/min
Cooling capacity (BTC-20 NF*) Q = 1 l/min
Cooling capacity (BTC-50 NF*) Q = 1 l/min
Heat exchanger
Supply voltage
Max. delivery height of pump head
Max. flow rate of pump head
Max. coolant outlet pressure/pump
pressure
Pump type
Coolant tank capacity
Coolant
Max. conductivity of coolant
Sound level
Protection type
EN - 8
Overview of the coolant circuit
A
Dimensions
702
590
General information
D Drain coupling
E Pump
F Coolant tank
F
E
301
50 Hz
1.24 kW
1.14 kW
1.09 kW
0.98 kW
3-row
115/230 V AC
35 m
10 l/min
3.9 bar
Centrifugal pump
8.0 l
BTC series or other ABICOR BINZEL coolant
MIG/MAG: 0–350 µS/cm, TIG: 0–250 µS/cm,
plasma: 0–30 µS/cm (observe manufacturer's
specifications if necessary).
58.5 dB(A)
IP 23 (suitable for indoor use only)
ABICOOLER 1300
B
C
D
60 Hz
1.30 kW
1.19 kW
1.14 kW
1.02 kW