10 Troubleshooting
10 Troubleshooting
Health risk caused by inhaling harmful dust
Cooled air is blown out of the device. This can lead to dust that has collected on the floor during the
welding process to be stirred up. Inhaling harmful dust can damage the respiratory tract.
► Check and wear your personal protective equipment.
► Place the device on a clean, dust-free surface.
Risk of injury from hot coolant
If the coolant tank is opened during or immediately after operation, coolant may spray out and cause
burns or irritation to skin and mucous membranes.
► Keep the coolant tank closed during operation.
► Wait at least 5 seconds after switching off before opening the screw cap of the coolant tank.
► Check and wear your personal protective equipment.
► Observe the documentation for the welding components.
► Note the warranty documentation provided.
► Contact your retailer or ABICOR BINZEL in the event of questions or problems.
Tab. 3
Faults and troubleshooting
Fault
Device does not function
Too little or insufficient
coolant flow
Cooling capacity too low Ventilator is defective.
High running noise level
EN - 20
WARNUNG
WARNUNG
Cause
Power supply is interrupted.
Motor/coolant pump is defective.
No coolant in the coolant tank.
Coolant level is too low.
Bottleneck or foreign object in the cooling circuit. ► Check the coolant hoses and connections.
Coolant pump fuse is defective.
Coolant pump is defective.
Coolant circuit is interrupted.
Air in the coolant circuit.
Coolant pump is defective.
Cooling unit is dirty.
Surrounding objects prevent the flow of air.
Coolant level is too low.
Coolant pump is defective.
ABICOOLER 1300
Troubleshooting
► Switch on the power supply.
► Check the electrical system and contact
customer service as needed.
► Replace the motor/coolant pump.
► Contact the service team.
► Replace the fuse.
6.2 Initial commissioning auf Seite EN-11
► Add coolant.
► Top up coolant.
► Flush the cooling circuit.
► Replace the fuse.
9.3 Replacing the fuse auf Seite EN-18
► Check the coolant circuit connections and
contact customer service as needed.
► Check the coolant hoses for damage and
replace them as needed.
► Bleed.
6.2.2 Bleed the device auf Seite EN-12
► Contact the service team.
► Contact the service team.
► Blow out the cooling unit with dry compressed
air.
► Install the device so there is sufficient distance
from other objects.
► Top up coolant.
► Contact the service team.