ABICOOLER 1300
Tab. 1
Dimensions (L×W×H)
Weight
Weight (including coolant)
*Mathematical approximate values.
Tab. 2
Ambient temperature
(operation, storage in a closed environment)
Ambient temperature (transport)
Relative humidity

5 Transport and installation

Risk of injury due to improper transport and installation
Improper transport and installation can cause the device to tip or fall over. This may result in serious
injuries.
► Check and wear your personal protective equipment.
► Ensure that all supply lines and cables do not encroach into the area in which employees are working.
► Place the device on a suitable base (flat, solid, dry) on which it will not topple over.
► Note the weight of the device when lifting it.
► Use an appropriate lifting tool with load handling attachment for transporting and installing the
► Avoid abrupt lifting and setting down.
► Do not lift the device over persons or other devices.
Health risk caused by inhaling harmful dust
Cooled air is blown out of the device. This can lead to dust that has collected on the floor during the
welding process to be stirred up. Inhaling harmful dust can damage the respiratory tract.
► Check and wear your personal protective equipment.
► Place the device on a clean, dust-free surface.
HINWEIS
Risk of material damage due to improper transport and installation
Improper transport or installation can cause the device to tip or fall over. This can result in material
damage and irreparable damage to the device.
► Protect the device against weather conditions, such as rain and direct sunlight.
► Use the device only in dry, clean and well-ventilated rooms.
► Ensure a clearance of 50 cm around the device when installing it to ensure optimal circulation of
► Prevent dust and other foreign substances from entering the device.
► Note the maximum angle of tilt of 10°.
General information
Ambient conditions for transport, storage and operation
WARNUNG
 4.2 Technical data auf Seite EN-8
device.
WARNUNG
cooled air.
5 Transport and installation
50 Hz
60 Hz
670 × 300 × 320 mm
22 kg
30 kg
-10 °C to +40 °C
-25 °C to +55 °C
Up to 90% at 20 °C