Fuse Protection For The Device; Initial Commissioning; Adding Coolant - Abicor Binzel ABICOOLER 1300 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ABICOOLER 1300

6.1 Fuse protection for the device

Fig. 5
A Fuse
► Device (115 V and 230 V) with a T2A fuse (5 × 20 mm).

6.2 Initial commissioning

6.2.1 Adding coolant

HINWEIS
Material damage due to unsuitable coolant
The use of unsuitable coolant can result in a limited cooling capacity and increased device wear.
The warranty does not cover damage to the device.
► Use BTC series coolant or a different ABICOR BINZEL coolant.
► When using a different coolant, ensure that it does not include aggressive, abrasive or resinous
► Use only demineralized water (permitted operating temperature +5°C to +40°C) or, after cleaning
HINWEIS
Material damage due to contaminated or conductive coolant
The use of contaminated or conductive coolant can lead to damage and increased wear in the device.
► Keep the coolant tank cap closed.
► Flush the cooling system before refilling with BTC coolant or other ABICOR BINZEL coolant with clean
► We recommend that you use a coolant filter (not included in the scope of supply).
► Regularly check the state of the coolant.
► Observe the recommended maximum conductivity of the coolant.
► Ensure that the coolant supply and return hoses have been correctly installed.
Fuse protection
components.
the device, a mixture of 25% monoethylenglycol and 75% demineralized water (permitted operating
temperature -10°C to +40°C), if ABICOR BINZEL BTC coolant or other ABICOR BINZEL coolant is
not available.
water to remove any deposits and contaminations.
 4.2 Technical data auf Seite EN-8
Coolant supply = blue-colored quick coupling, coolant return = red-colored quick coupling.
A
Switch off the device.
1
Plug in the power plug to establish power supply.
2
6 Commissioning
EN - 11

Publicidad

Tabla de contenido
loading