Bleeding The Cable Assembly - Abicor Binzel ABICOOLER 1300 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ABICOOLER 1300

6.2.3 Bleeding the cable assembly

Proper cooling is ensured only if the entire cooling system has been bled. The cable assembly must bled at
the time of initial commissioning and every time the device is fully bled.
Connect the cable assembly's coolant hoses to the device, ensuring that the cooling circuit is closed.
1
Remove the coolant tank cap and keep the coolant tank open until the bleeding process is complete.
2
Remove the coolant return hose from the red-colored quick coupling and hold it over the coolant tank's
3
opening.
Switch on the device.
4
Seal the coolant hose or kink it and then open it abruptly. Repeat this process until coolant flows
5
continuously and without bubbles.
Switch off the device.
6
Connect the coolant return hose to the red-colored quick coupling.
7
Check the coolant level and fill as needed.
8
Seal the coolant tank.
9
Press air out of the tool for device bleeding.
4
If coolant is also drawn up when the piston is pulled
up, proceed as follows:
Open the coolant tank's cap.
5
Pull off the quick coupling of the tool for device
6
bleeding.
Press the coolant out of the tool for device
7
bleeding into the coolant tank.
Reconnect the quick coupling of the tool for
8
device bleeding.
Repeat the procedure 2x.
9
Close the coolant tank cap.
10
6 Commissioning
EN - 13

Publicidad

Tabla de contenido
loading