Malfunctions - JAC TRADILEVAIN TL40 Traducción Del Manual De Uso Original

Ocultar thumbs Ver también para TRADILEVAIN TL40:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51

10. MALFUNCTIONS

WARNING: The machine must be isolated from the power supply before attempting any work on it.
Error code
Should the problem persist, please contact your dealer.
Shut off the power to the machine at the isolator switch,
wait 1 minutes and reset the isolator switch. If the fault is
still there when the power is switched on again, contact
your dealer.
Shut off the power supply and clean your evaporator
(8.3). If the fault is still there when the power is switched
on again, contact your dealer.
Lack of gas in the system: contact your dealer.
Insufficient quantity of mother dough.
Open / close your cover, check that the seal is fitted
correctly and that there is nothing in the way of closing.
If the fault is still there when closing, contact your dealer.
Open the cover and clean your level sensor. If the fault
is still there when closing, contact your dealer.
Temperature measuring tube: contact your dealer.