Before Startup; Unpacking; Start Up; Electrical Connection - Kärcher HD 7/16-4 Cage Manual Del Usuario

Ocultar thumbs Ver también para HD 7/16-4 Cage:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36

Before Startup

Unpacking

– Check the contents of the pack before
unpacking.
– In case of transport damage inform ven-
dor immediately
Check oil level
 The oil level must be at the centre of the
oil level display.
Activate deaeration of oil container
 Unscrew the screw plug.
 Screw in enclosed oil filling screw.
 Close cover.
Attaching the Accessories
 Connect spray lance to trigger gun.
 Install nozzle with nozzle screw at the
spray lance.
 Bolt the high-pressure hose on to the
hand spray gun.
 Fasten the high pressure hose to the
high pressure connection.
Mounting the cable / hose rack
 If required, attach accompanying cable
/ hose rack to the wall.
or
Illustration
 Attach the enclosed cable/hose rack to
the bottom of the device.
Attaching the holder for the trigger
Note:
Not all unit models are equipped with the
holder for the trigger gun.
Illustration
 Attaching the support.
gun

Electrical connection

DANGER
Danger of injury by electric shock.
The appliance may only be connected to al-
ternating current.
The appliance should always be connected
to the electrical mains using a plug. It is for-
bidden to permanently connect the appli-
ance to the power supply. The plug is only
for mains separation.
Use the extension cord that has an ade-
quate cross-section (see "Technical Data")
and unwind it fully from the cable drum.
For connection values, see type plate/tech-
nical data.
Water connection
Connection to the water supply
According to applicable regula-
tions, the appliance must never be
used on the drinking water net
without a system separator. En-
sure that the connection of your building
water installation on which the high-pres-
sure cleaner is operated is equipped with a
system separator pursuant to EN 12729
Type BA.
Water that was flowing through a system
separator is considered non-drinkable.
CAUTION
Always connect the system separator to
the water supply, never directly to the appli-
ance!
For connection values refer to technical
specifications
 Connect the supply hose (minimum
length 7.5 m, minimum diameter 3/4") to
the water connection point of the ma-
chine and at the water supply point (for
e.g. a tap).
Note:
The supply hose is not included.
 Open the water supply.
– 5