Pump Description - Wilo Smart 25/4 Instrucciones De Instalación Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
ENGLISH
Unauthorized modification and
manufacture of spare parts
Alterations to the pump or installa-
tion may only be carried out with
the manufacturer's consent.
The use of original spare parts and
accessories
authorized
manufacturer will ensure safety.
The use of any other parts may
invalidate claims invoking the liabi-
lity of the manufacturer for any
consequences.
Unauthorized operating methods
The operating safety of the pump
or installation supplied can only be
guaranteed if it is used in accor-
dance with paragraph 1 of the
operating instructions. Under no
circumstances should the limit
values given in the data sheet be
exceeded.
3 Transport/Interim
storage
ATTENTION!
The pump contains
electronic
nents and must be
protected
external
and mechanical da-
mage
(shock/impact).
It
exposed to tempe-
ratures outside the
range
+50°C.
12
by
the
compo-
against
moisture
should
not
be
-10°C

4 Pump description

The pump is fitted with a wet run-
ner motor. The pumping medium
lubricates and cools the friction
bearing and rotor.
No motor protection is required.
Even the maximum overload cur-
rent cannot damage the motor. The
motor operates non-overloading.
Control mode: Automatic
The pump differential pressure falls
within the set control channel.
The automatic pump control adapt
the delivery head within the control
channel to the volume flow and as
such prevent any disruptive flow
noises inside the heating installati-
on.
Control channel selection (diffe-
rential pressure range) (fig. 7)
In order to guarantee efficient ope-
ration of the heating installation
and optimum adaptation of the
pump to the load on the hydraulic
installation, it is important to select
the right control range. The pump
control channel is selected using a
3-stage selector switch in accor-
dance with the installation require-
ments. The pump operates within
the chosen control range (charac-
teristic diagram) and adapts conti-
nuously to the fluctuating power
requirements of the installation, in
to
particular when thermostat valves
are used.