STBS700 PUMP LED, BUTTON, ALARM, AND CONTROLLER BEHAVIORS
Z Control LED and
Power LED
Alarm Behaviors
Alarm
Z Control LED
Silence Button
Press/release
Hold 3 seconds
Hold 4 seconds
Hold while applying AC to
STBS700 controller
Hold 12 seconds
Communications
Communication with
Basement Sentry app
Communication with
Basement Sentry app lost
Alarm condition present
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.
Power LED is on when AC power is present.
Input LED on solid.
Alarm triple beeps continuously.
LED is solid when connected to router and Basement Sentry app.
LED is off when STBS700 controller is in AP mode.*
LED blinks when WIFI setup is in process.
LED blinks faster if STBS700 controller is attempting to reconnect to a
known router.
LED alternates blinking fast then slow when STBS700 controller is
connected to router, but internet is lost.
Silences alarms. LED that is in alarm stays on (or blinks) until
STBS700 controller is reset.
Resets any active alarms and returns STBS700 controller to standby
mode.
Initiates an LED and Alarm Test. Will flash and double beep 3 times.
STBS700 controller will enter AP mode.* For STBS700 controller to
revert to previous WIFI settings, power cycle again.
Complete reset of STBS700 controller to factory settings, including
erasing WIFI settings. STBS700 controller will enter AP mode.*
Communication is nearly continuous.
Notification sent to user after 10 minutes of no communication.
Immediate communication to Basement Sentry app.