SUMP PUMP INSTALLATION (CONTINUED)
6. B. Position second float float at desired 'on level' on the
discharge pipe.
6. C. Attach mounting bracket to the discharge pipe as shown,
using hose clamp (included).
WARNING: DO NOT install high water float in direct line
of incoming water or close to the vent hole.
7. Make sure your hands are dry and you are not standing
in water. Connect the pump to a properly-grounded, GFCI
electrical outlet.
WARNING: Do not use an extension cord.
NOTE: Tape the electrical cord to the discharge pipe to
prevent it from interfering with the motion of the float.
6B
6C
7