geberit MFP 2 Manual De Operación página 26

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 73
EN
Pressing with Geberit
pressing attachments
WARNING
Risk of injury caused by flying
fragments
▶ Wear protective goggles and a
WARNING
Risk of injury caused by the use
of incorrect pressing
attachments
▶ Only use pressing
To improve ease of use, the pressing
head of the pressing tool can be
turned to any position up to 180°
before pressing. The pressing head
can only be rotated before the
pressing procedure.
26
protective helmet.
attachments that correspond
to the diameter of the
pressfittings to be processed.
Prerequisite
Pipe ends are deburred and clean.
The pipe section and pressfitting are
fitted together according to the
installation manual of the piping system.
The pressing attachment is inserted
correctly.
The hydraulic valve of the pressing tool
is open and the handle has been pushed
backwards.
1
Fit the pressing attachment to the
pressfitting correctly and do not tilt.
→ See user manual for the pressing
attachments in question.
CAUTION
Danger of crushing
▶ Keep hands away from the
pressing attachment.
27021600880296075-1 © 02-2018
968.243.00.0 (00)

Publicidad

Tabla de contenido
loading

Tabla de contenido