9 Troubleshooting

NOTICE
• If the measures described below are not successful, please consult your dealer or the manufacturer.
• Please also consult the operating instructions for the welding components, such as the power source,
The following faults may occur during operation:
Fault
ABIDRIVE CW is not ready
for operation.
Wire is not fed.
No welding arc.
Torch body or power source
overheating.
Tab. 7

10 Dismounting

Risk of injury due to unexpected start-up
For the entire duration of maintenance, servicing, dismounting and repair work, the following instructions
must be adhered to:
• Switch off the power source.
• Close off the gas supply.
• Switch off the entire welding system.
• Pull the mains plug.

Risk of crushing

Upper limbs can become crushed or caught at the covering hood.
• Do not reach into the danger zone.
• Wear protective gloves.
welding torch system, re-circulating cooling unit, etc.
Cause
• Main switch is switched off.
• Mains connection interrupted.
• Motor is defective.
• Fault of the motor control card.
• Power supply to the workpiece
• Power source or control system
• Control lead interrupted.
• Insufficient flow of coolant.
• Welding current too high.
• Coolant hose or liquid-cooled
• Tungsten electrode loose.
Troubleshooting
DANGER
WARNING
or torch interrupted.
defective.
power cable constricted or
closed.
9 Troubleshooting
Solution
• Switch on ABIDRIVE CW.
• Establish mains connection.
• Switch unit to currentless state,
replace motor.
• Replace motor control card.
• Close the power circuit.
• Repair.
• Replace.
• Check the proper function and
performance of the coolant
recirculator.
• Reduce.
• Check the flow and replace if
necessary.
• Tighten with the torch cap.
EN - 15