Transducer Installation

3.5.1

General Information

Mounting Supplies
The following items will be needed to mount the transducers:
● Flat blade screwdriver
● Mounting Frames or Mounting tracks
● Tape, chalk and a ruler or measuring tape
● Mounting Straps
● Spacer Bar
● Mounting Guide (for Direct Mount)
● CC129 Pipe Damping Film
● Ultrasonic coupling compound
● Transducers (matched set)
Transducer Selection
Refer to the Transducer Selection Chart to select the correct transducer size.
Note
Selection chart lists High Precision transducers for steel pipe with outer diameter/wall
thickness ration >10.
Table 3- 5
B1H
B2H
B3H
C1H
C2H
D1H
D2H
D3H
D4H
SITRANS FUG1010 Quick Start
Operating Instructions (Compact), 1/2009, CQO:QSG005 Revision B
Transducer Selection Chart
Transducer
Size Code
Pipe Wall (mm)
Min. Max.
2.0
3.0
3.0
4.1
2.7
3.3
4.1
5.8
5.8
8.1
8.1
11.2
11.2
15.7
7.4
9.0
15.7
31.8
Commissioning
3.5 Transducer Installation
Pipe Wall (inches)
Min. Max
0.08
0.12
0.12
0.16
0.106
0.128
0.16
0.23
0.23
0.32
0.32
0.44
0.44
0.62
0.293
0.354
0.62
1.25
27