Commissioning
3.4 Setting the Parameters
4. Trigger <ENTER> sensor to save the Site name.
5. Trigger <Left Arrow> and return to [Channel Setup]. Trigger <Down Arrow> to select
Select Pipe Class
1. Trigger <Right Arrow> to select [Pick Pipe Class].
2. Trigger <Right Arrow> again. Trigger the <Up/Down Arrows> to scroll to desired Pipe
3. Trigger <ENTER> to select Pipe Class.
4. Select Pipe Size from pre-defined list or enter manually. Trigger <Right Arrow> sensor.
5. Trigger <ENTER> to save Pipe Size selection.
Note
Pre-programmed Pipe Size and relevant pipe parameters will appear in menu cells. To
enter dimensions manually if pre-programmed dimensions do not match application, refer
to flowmeter manual for details.
Select Gas Parameters
It is recommended to edit the Gas Parameters before continuing. If reliable data is available
for gas specific heat ratio, gas viscosity, sound velocity or gas compressibility factor, these
settings should be modified. It is particularly important that the approximate (nominal)
operating pressure be entered to allow for proper flow profile compensation.
24
[Pipe Data].
Class.
Trigger <Up/Down Arrows> to scroll to select desired Pipe Size.
Operating Instructions (Compact), 1/2009, CQO:QSG005 Revision B
SITRANS FUG1010 Quick Start