7
COMMISSIONING
7.3
Setting
18
% of sensing range
25
20
15
18%/90%
6%/90%
10
1
2
5
0
0
50
100
150
200
(1.97)
(3.94)
(5.91)
(7.87)
Distance in mm (inch)
Figure 3: HTB18, % of sensing range
HTB18L:
% of sensing range
20
15
10
6%/90%
1
5
0
0
50
100
150
200
(1.97)
(3.94)
(5.91)
(7.87)
Distance in mm (inch)
Figure 4: HTB18L, % of sensing range
Figure 5: Description of the sensing range areas
Sensing range setting
1
2
3
A = detection distance (depending on
object remission)
B = adjustment range
90%/90%
3
250
300
(9.84)
(11.81)
x = 250 mm, y = 15 mm
(= 15% of 250 mm)
20%/90%
2
1
2
90%/90%
3
3
250
300
(9.84)
(11.81)
A = detection distance (depending on
object remission)
B = adjustment range
5 20
150
3 20
150
200
3 20
150
A
B
white back-
ground (90%)
x
y
30
30
30
A
B
8017850.1A15 / 2020-12-14 | SICK
Subject to change without notice
300
250
250
300
250
300