7
COMMISSIONING
en
7.3

Sensing range setting

28
O P E R A T I N G I N S T R U C T I O N S | WLA16
Function reserve
1,000
WLA16P-xxxxx1xx
100
5
4
10
1
2
3
1
0
2
4
6
(6.56)
(13.12)
(19.69)
Figure 22: Characteristic line 4: Chemical-
resistant reflector
Reflector PL10F CHEM
1
Reflector PL20 CHEM
2
Reflector P250 CHEM
3
Reflector P250H
4
Reflector PL40A Antifog
5
WLA16x-xxxxxx3xAxx with teach-in button:
There must not be any objects located between the WLA16 and the reflector. The
sensitivity is reduced by pressing the teach-in button (approx. 1-3 sec.). This primarily
suppresses false switching to extremely depolarizing objects. The sensing range is also
reduced, and therefore the operating reserve as well. Lead an object into the path of
the beam. The yellow LED goes out, meaning the object is detected and the setting is
correct.
1
0
1.4 2
2
0
3
0
4
0
5
0
0
0
Sensing range
Figure 23: Bar graph 4: Chemical-resistant
Sensing range
Reflector PL10F CHEM
1
Reflector PL20 CHEM
2
8
10
Reflector P250 CHEM
3
(26.25)
(32.81)
Distance in m (feet)
Reflector P250H
4
Reflector PL40A Antifog
5
2.4
3.5
3.5
5
4
6
6
8
2
4
6
8
(6.56)
(13.12)
(19.69)
(26.25)
Distance in m (feet)
Sensing range typ. max.
reflector
8020348.1DS6/2021-11-24 | SICK