Default Parameter Recovery; Alarms - Sagi XE70 Instrucciones Originales - Manual De Uso E Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 163
Press the on/sby/enter key to confirm your selection and enter the mode
for reading probes or changing parameters.
The current value blinks on the display.
Use the keys
only.
Press the on/sby/enter key to exit or confirm the selection of the
parameter new value; the setting stops blinking.
You can leave the programming phase by waiting for 30 seconds without operating on the
card, or pressing
In both cases, there you will hear 3 consecutive, short beeps and the display will
temporarily show [ESC].
Information accessible to qualified staff only
On starting the appliance, a "LAMPTEST" phase will start.
If you press the on/sby/enter key 3 times consecutively during this phase,
all default parameters will be reset.
The display shows [rLd] indicating the reset of the values pre-set by the
manufacturer.
ATTENTION: the default values in memory refer to the configurations (TN, BT) exclusively.
Room probe error
If the room probe is broken or the relevant connection interrupted, the display shows the
label [E0].
The appliance keeps operating in storing according to the values given to parameters C5
and C6.
The inner fan keeps operating according to the value given to F7.
The defrost control is automatically inhibited and the card self-calibration process de-
activated.
Evaporator fan error
If the evaporator probe is broken or the relevant connection interrupted, the display shows
the label [E1].
to select the new value, applicable to parameters
for 5 seconds.

DEFAULT PARAMETER RECOVERY

ALARMS

APPLIANCE WITH BROKEN PROBES
28