holding the outer sheath of the cable firmly
and that the two leads are correctly fixed at
the terminals crews.
4
3
WARNING: NEVER use a light socket.
NEVER connect the live (L) or
neutral (N) wires to the earth
pin marked E or
WARNING: 115 V units have to
be operated via a fail-safe isolating
transformer with an earth screen between
the primary and secondary winding.
For 115 V units with a power rating exceeding 1500 W,
we recommend to fit a plug to BS4343 standard.
Using an extension cable
If an extension cable is required, use an approved
extension cable suitable for the power input of this
tool (see technical data). The minimum conduc tor size
2
is 1.5 mm
. When using a cable reel, always unwind
the cable completely.
Also refer to the table below.
Conductor size (mm
2
)
Cable rating (Amperes)
0.75
6
1.00
10
1.50
15
2.50
20
4.00
25
Cable length (m)
7.5
15
Voltage
Amperes
Cable rating (Amperes)
115
0 - 2.0
6
2.1 - 3.4
6
3.5 - 5.0
6
5.1 - 7.0
10
10
7.1 - 12.0
15
15
12.1 - 20.0
20
20
230
1
Voltage drops
2
Inrush currents cause short-time voltage drops.
Under unfavourable power supply conditions, other
equipment may be affected.
If the system impedance of the power supply is lower
than 0.25 ø, disturbances are unlikely to occur.
ASSEMBLY AND ADJUSTMENT
.
MOUNTING AND REMOVING THE GUARD
DW831 - Mounting (fig. B1 & C1)
25
30
45
60
DW831 - Removing (fig. B1 & C1)
6
6
6
6
10
6
6
6
15
15
6
10
15
20
20
15
20
20
25
20
25
25
-
25
-
-
-
0 - 2.0
6
6
2.1 - 3.4
6
6
3.5 - 5.0
6
6
5.1 - 7.0
10
10
7.1 - 12.0
15
15
12.1 - 20.0
20
20
WARNING: Prior to assembly and
adjustment, always turn tool off and
disconnect tool from power source before
making any adjustments or removing/
installing attachments or accessories.
Before reconnecting the tool, depress
and release the trigger switch to ensure
that the tool is off.
WARNING: To reduce the risk
of serious personal injury, turn
tool off and disconnect tool from
power source before making any
adjustments or removing/installing
attachments or accessories. Before
reconnecting the tool, depress and
release the trigger switch to ensure
that the tool is off.
WARNING: Guards must be used with
this grinder.
• Place the angle grinder on a table, spindle up.
• Align the lug (6) with the slot (7) in the bracket.
• Press the guard (8) down and turn it in the
direction of the arrow (fig. B1).
WARNING: The guard locking pin (9)
prevents the guard from coming loose.
• Hold the tool in your hand.
• Rotate the guard (8) in the direction of the arrow
(fig. C1).
• Use a screwdriver to press the locking pin (9) in
the slot.
• Release the guard.
E N G L I S H
6
6
6
6
6
6
6
6
6
6
10
15
10
10
15
15
15
15
20
20
20
20
25
-
27