8.1. Mount flat fan nozzle
To align the blowing air, the flat fan nozzle has to be mounted and
aligned.
■ Push the flat fan nozzle [2-6] onto the front nozzle [2-7] of the dry jet
gun until locks in place.
8.2. Mount connection nipple
Notice!
The connection nipple is only included in the standard version. For all
other versions, the connection nipple has to be supplied by the custom-
er. The SATA connection nipple (Art. No. 6981) is necessary for connect-
ing the dry jet gun to a SATA dry jet 2 stand or SATA dry jet 2 stand jum-
bo.
■ Screw connection nipple [2-5] onto the air connection of the dry jet gun
[2-4] (torque: 1 Nm).
8.3. Mount sieve
Notice!
The sieve is not suitable for cleaning and must be replaced when
clogged (see chapter 10).
The sieve is symmetrical in design. It can be fitted in any direction.
■ Press a sieve [2-1] into the filter holder [2-2] until it locks in place.
9. Normal Operation
Explosion risk
The use of unsuitable compressed air hoses may cause explosions.
→ Only use solvent-resistant, antistatic, undamaged and technically
flawless compressed air hoses with permanent pressure resistance of
minimum 10.0 bar , inner diameter of minimum 9 mm, such as the SATA
air hose (Art. No. 53090).
64
Warning!