After identifying the pin 1 and pin 2. Both wires of the communication cable must be connected
to the J8 terminal of the inverter.
1. Pass the CAN communication cable though the dedicated cable
gormet.
2. Connect both wires to the terminal J8 BMS as shown in the previous
figure, respecting the printed instructions on the screen-printed
electronic card (CAN_L, CAN_H):
3. Guide the cable and hold it if necessary on the plastic support.
4. Check that the connection is tight.
Once all the previous steps have been followed and the inverter is properly wired, the
commissioning of the inverter can be done.
2.2

Switch on the inverter from battery

The inverter can be supplied from the WECO 5K3 battery, without configuration. To do so, once
all the previous steps have been completed, the power button must be pressed for 2 seconds.
ABH2010IMC23_
Use and settings of the INGECON SUN STORAGE 1Play TL M working with BYD B-BOX
Premium HVS/HVM
ISS 1Play TL M
Ethernet cable
Pin 1
Pin 2
ISS 1Play TL M
J8 BMS CAN_H
J8 BMS CAN_L