12
TECHNICAL DATA
12
Technical data
Sensing range max.
(with reflector PL80A)
Light band dimen‐
sions / distance
approx.
Minimum detectable
object (MDO)
Minimum distance
between sensor and
reflector
Supply voltage U
B
Current consumption
Output current I
max.
Communication mode
en
IO-Link
Max. response time
Switching frequency
Enclosure rating
Protection class
Circuit protection
Ambient operating tem‐
perature
1)
RAY26P-xxxxx3: sensing range depends on the selected MDO (selectable via IO-Link):
3 mm = 0 ... 2 m
5 mm = 0 ... 3 m
10 mm = 0 ... 4.5 m
2)
Factory setting see data sheet, MDO is selectable via IO-Link
3)
16 VDC to 30 VDC, without load
4)
10 VDC to 16 VDC, without load
5)
Signal transit time with resistive load in switching mode. Deviating values possible in COM2 mode.
6)
With a light/dark ratio of 1:1 in switching mode. Deviating values possible in IO-Link mode.
7)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit protected
8)
Avoid condensation on the front screen of the sensor and on the reflector.
9)
Allowed temperature change after Teach +/- 20 K
36
O P E R A T I N G I N S T R U C T I O N S | RAY26
RAY26P-xxxxx1
RAY26P-xxxxx3
0 ... 1.5 m
0 ... 4.5 m
20 mm x 9 mm (1
55 mm x 9 mm (1m)
m)
≥ 1 mm
≥ 3 mm, 5 mm or
10 mm
1)
0 mm
10 ... 30 V DC
≤ 25 mA
, < 50 mA
3)
4)
≤ 100 mA
COM2
1.1
≤ 3 ms
5)
170 Hz
6)
IP66, IP67
III
A, B, C, D
7)
–40 °C ... +60 °C
8)9)
RAY26P-xxxxx5
RAY26P-xxxxx9
0 ... 3 m
0 ... 4.5 m
≥ 5 mm
≥ 10 mm
RAY26P-xxxxxA
0 ... 4.5 m
≥ 10 mm, 15 mm,
20 mm, 25 mm or
30 mm
2)
≤ 500 μs
5)
1000 Hz
6)
8022178.1BXO /2021-05-26 | SICK
Subject to change without notice