8 Decommissioning
Fig. 5
A Extraction arm
B Handle
C Service door
D <ON/OFF> switch
H
G
F
Adjust the extraction arm (A) to accommodate the work task.
1
Adjust the extraction hood (F) to accommodate the work task. The extraction hood (F) must be located
2
approx. 20 cm above the welding point during operation.
Establish an electrical connection.
3
Switch on the LED light (G) on the extraction hood (F).
4
Adjust air volume to the work task.
5
6.3 Controlling the volume flow on page EN-16
► Turn the <ON/OFF> switch (D) to <I>.
8 Decommissioning
Turn the <ON/OFF> switch (D) to <O>.
1
Disconnect the device from the power supply.
2
9 Maintenance and cleaning
Scheduled maintenance and cleaning are prerequisites for a long service life and trouble-free operation.
The maintenance cycle is determined by the work environment and by the length of the scheduled intervals
between maintenance of the devices. The maintenance cycle is usually three months. If the device is
operated for more than 8 hours a day, the maintenance intervals should be changed as needed.
Health risk caused by inhaling harmful dust
The device contains harmful dust that can collect on surfaces and penetrate the ambient air as of the first
use. It can damage the respiratory tract when inhaled.
► Check and wear your personal protective equipment.
► Maintenance and cleaning of the device must only be carried out in rooms with locally filtered forced
► Do not open the service door until at least one minute has passed since the device was switched off.
► Immediately remove dust deposits from the environment with a dust class H industrial vacuum cleaner
► Replace the contaminated filter elements (pre-filter, primary filter) in their entirety.
EN - 16
Assembly and use
WARNING
ventilation.
or a damp cloth.
E 4 × castors
F Extraction hood
G LED light
H Light switch
A
B
C
D
E
®
xFUME
FLEX