9.4 Cleaning outer surfaces

Clean outer surfaces with a suitable industrial vacuum cleaner (dust class H in accordance with
1
DIN EN 60335-2-69 Appendix AA) or a damp cloth.
Dispose of cleaning residues/cloths in accordance with local regulations.
2

9.5 Replacing the extraction arm

NOTICE
Reduced extraction capacity due to a defective extraction hose
Damage to the extraction hose and leaks negatively impact extraction performance.
► Check the extraction hose regularly and replace it as needed.
9 Maintenance and cleaning
Fold the upper end of the rubber sleeve on the
1
extraction hood so that the gripping clamp is
accessible. Loosen the gripping clamp screw.
Retract the extraction hose.
2
Cut open the cable tie.
3
Disconnect the cable connections.
4
Loosen the screw between the connector and
5
profile tube and remove the extraction hood.
Fold the upper end of the rubber sleeve on the
6
device so that the gripping clamp is accessible.
Loosen the gripping clamp screw.
Remove the extraction hose in the direction shown
7
and replace it with a new one.
 6.1 Mounting the extraction arm on page EN-13
step 5 and step 6
 6.1 Mounting the extraction arm on page EN-13
step 12 to step 18
EN - 19