9 Maintenance and cleaning

9.3 Replacing the primary filter

The primary filter cannot be cleaned; it must be completely replaced.
Cleaning the primary filter with compressed air or a hammer is not permitted.
EN - 18
A
Remove the spring clamp (A) and filter pad (B).
5
Dispose of the filter pad (B) in accordance with
6
local regulations.
B
 12 Disposal on page EN-22
Insert a new filter pad (B) into the filter grill (C).
7
Insert the spring clamp (A).
8
C
Insert the pre-filter.
9
Close the service door and lock it using
10
a square wrench.
Use the <ON/OFF> switch to switch the device to
1
<O>.
 Fig. 2 Assembly and use on page EN-11
Pull out the mains plug.
2
Unlock and open the service door using a square
3
wrench.
Remove the primary filter.
4
Dispose of the primary filter in accordance with
5
local regulations.
 12 Disposal on page EN-22
Insert the primary filter.
6
Close the service door and lock it using
7
a square wrench.
®
xFUME