Do not work without the mod-
el table installed and locked
(„click"). Small parts or fingers
can be drawn into the trimmer,
resulting in serious injury.
Remove the trimmer table only
after the grinding wheel has
come to a complete stop and the
front cover is opened.
Operate the equipment only
under supervision
It is the responsibility of the op-
erator that national regulations
during operation and regarding
a repeated safety inspection of
electrical equipment are com-
plied with. For Germany these
are the regulation 3 by DGUV
(German Statutory Accident
Insurance) in relation with VDE
(Association for Electrical &
Electronic Technology) 0701-
0702.
Additional notes for dry trimming:
The extraction must be selected
to match the dust being gener-
ated (if necessary, consult the
responsible professional organi-
zation).
Operating the unit can result in a
very high noise level >>> always
wear ear protection.
3.1 Liability Exclusion
Renfert GmbH shall be absolved from
all claims for damages or warranty if:
•
The product is employed for any pur-
poses other than those cited in the
operating instructions;
•
The product is altered in any way oth-
er than those alterations described in
the operating instructions;
•
The product is repaired by other than
an authorized facility or if any but
Renfert OEM parts are employed;
•
The product continues to be em-
ployed, despite obvious safety faults.
EN
4. Commissioning /
Operation
First, check to make sure that your
mains power corresponds with the
power requirements given on the trim-
mer nameplate.
The type of usage wet- (see pt. 4.1 and
4.2) or dry-trimming (see pt. 4.1 and
4.3) must be determined prior to use.
4.1 Mounting the Trimmer Disc
Please refer to the trimmer disc instruc-
tions (resp. to pt. 5.1 in this instructions)
for the mounting procedure.
Range of application of the discs:
• Klettfix for wet trimming
• Marathon for wet or dry trimming
• Infinity for wet trimming
4.2 Wet Trimming
1. Set the unit up near the water source /
drain, with a plaster trap (Fig. 1).
2. Connect the drain hose to the trim-
mer (Fig. 2). Turn the drain hose
on the connecting branch counter
clockwise and fix with a hose clamp
(Fig. 2b)!
3. Position the trimmer hose in the drain
(Fig. 3a / 3b).
4. Connect the water hose to the trimmer
(Fig. 4a / 4b). Observe the necessary
water pressure (see pt. 8 / technical
specifications)!
5. Connect the water hose to a water
supply with a shutoff tap (Fig. 5).
6. Open the water supply (Fig. 6a) and
check for leaks (Fig. 6b).
7. Plug the power cord into the wall outlet
(Fig. 7).
8. Switch the unit on (Fig. 8).
9. Adjust the water flowrate (Fig. 9).
Attention: the water inlet is closed on
delivery.
The MTplus is now ready for use as a wet
trimmer.
- 2 -