Descargar Imprimir esta página

Connecting The Accessories - RIB SUPER 3600 Manual Del Usuario

Ocultar thumbs Ver también para SUPER 3600:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 3
SIMPLIFIED INSTRUCTIONS FOR SUPER 3600 WITH S1-CRX/R2
1° Connecting the motor and limit switch (done in the factory)
NO
NC
C
POWER
230 VAC
CAPACITOR
M
3 – LIMIT SWITCH ADJUSTMENT
Release the operator using handle "A" as indicated below,
therefore releasing the G nuts.
Move the mobile part manually to establish the direction of the
H cams' movement both in opening and closing.
With the gate open and closed, put the two F limit switches on
the P handles so that they are pressed by the H cams.
Lock the G nuts.
To be able to open the gate manually, open the cover with
the appropriate key and turn handle "A" in an anti-clockwise
direction.
To restore the electric functioning operate in the opposite
direction.
N.B. The H cams must press the electric micro switches before
the mobile part touches the mechanical stops.
NO
NC
C
BLUE
1
2
3
4
The motor is set to open towards the right.
If opening is to the left, the LSO and LSC wires on terminal block J3 and the V
and W wires on terminal block JA must be reversed.
A+A- Observe the polarity of the
photocells' electrical supply
A* A S
C NC
A* A S
5
Without Edge, jumper COM-EDGE
IMPORTANT
2° Connecting the accessories
ANTENNA – Use an RG58 co-axial cable

Publicidad