Descargar Imprimir esta página

Connecting The Accessories - RIB SUPER 2200 Manual Del Usuario

Ocultar thumbs Ver también para SUPER 2200:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 3
SIMPLIFIED INSTRUCTIONS FOR SUPER 2200 WITH S1
1° Connecting the motor and limit switch (done in the factory)
NO
NO
NC
NC
C
C
BLUE
CAPACITOR
BROWN
BLUE
M
BLACK
MOTOR
3 – LIMIT SWITCH ADJUSTMENT
Release the operator using handle "A" as indicated below,
therefore releasing the G nuts.
Move the mobile part manually to establish the direction of the
H cams' movement both in opening and closing.
With the gate open and closed, put the two F limit switches on
the P handles so that they are pressed by the H cams.
Lock the G nuts.
To open the gate manually, the sump with the appropriate key
must be opened. Insert the RIB hex key in the release screw
and turn it 3 times anti-clockwise.
To restore the electric functioning operate in the opposite
direction.
N.B. The H cams must press the electric micro switches before
the mobile part touches the mechanical stops.
4
3
1
2
3
4
5
Without Edge, jumper COM-EDGE
The motor is set to open towards the right.
If opening is to the left, the LSO and LSC wires on terminal block J3 and the V
and W wires on terminal block J2 must be reversed.
2° Connecting the accessories
A+A- Observe the polarity of the
photocells' electrical supply
A* A
S
C
NO
NC
A+ A- S
IMPORTANT
ANTENNA – Use an RG58 co-axial cable
4
3

Publicidad

loading