SIMPLIFIED INSTRUCTIONS FOR K800-1400-2200 WITH S1
1° Connecting the motor and limit switch (done in the factory)
NO
NO
NC
NC
C
C
BLUE
CAPACITOR
BROWN
BLUE
M
BLACK
MOTOR
3° Installing and adjusting the limit plate cams
Position the cams on the rack.
Tighten the two screws to lock them. How to finely adjust cam
intervention is explained below.
4
3
1
3
4
2
5
The motor is set to open towards the right.
If opening is to the left, the LSO and LSC wires on terminal block J3 and the V
and W wires on terminal block J2 must be reversed.
A+A- Observe the polarity of the
photocells' electrical supply
A* A
S
C
NC
A* A
S
Without Edge, jumper COM-EDGE
Release the motor (turn the key counter clockwise until the limit is
reached without forcing) and move the gate by hand
Check when the cams are activated.
Note: The cams must press the electric microswitches before the mobile
part touches the mechanical stops.
IMPORTANT
2° Connecting the accessories
ANTENNA – Use an RG58 co-axial cable
4
3