Technical Parameters - Elko EP CRM-91HE Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17

Technical parameters

Number of functions:
Supply terminals:
Voltage range:
Power input (max.):
Max. dissipated power
(Un + terminals):
Supply voltage tolerance:
Supply indication:
Time ranges:
Time settings:
Time deviation:
Repeat accuracy:
Temperature coeffi cient:
Output
Number of contacts:
Rated current:
Breaking capacity:
Inrush current:
Switching voltage:
Output indication:
Mechanical life:
Electrical life (AC1):
Controlling
Control. voltage:
Power the control input:
Load between S-A2:
Glow tubes connetions:
Control. terminals:
Impulse length:
Reset time:
Other information
Operating temperature:
Storage temperature:
Electrical strength:
Operating position:
Mounting:
Protection degree:
Overvoltage cathegory:
Pollution degree:
2
Max. cable size (mm
):
Dimensions:
Weight:
Standards:
Potentiometer
It is possible to connect the external operating potentiometer up to the distance of
maximally 10 meters (32.8 ft.) from relay CRM-91HE, for example in switchboard. The
external potentiometer has cover IP65 from the front side and IP20 from the rear side.
It is absolutelly necessary to connect potentiometer with the device in correct way.
The terminals on the device must be connected to the equally marked terminal on the
potentiometer.
Potentiometer:
Protection degree:
2
Max. cable size (mm
):
Weight:
M 22x1
CRM-91HE
10
A1 - A2
AC/DC 12 - 240 V (AC 50 - 60 Hz)
AC 0.7 - 3 VA / DC 0.5 - 1.7 W
4 W
-15%; + 10%
green LED
0.1 s - 10 days
rotary switch and external potentiometers
5 % - mechanical setting
0.2 % - set value stability
0.01 % / °C, at = 20 °C
1x changeover / SPDT (AgNi / Silver Alloy)
16 A/AC 1
4000 VA/AC1, 384 W / DC
30 A / < 3 s
250 V AC / 24 V DC
multifunction red LED
3x10
7
5
0.7x10
AC/DC 12 - 240 V (AC 50 - 60 Hz)
AC 0.025-0.2 VA/DC 0.1-0.7 W
Yes
No
A1-S
min. 25 ms / max. unlimited
max. 150 ms
-20 °C to 55 °C (-4 °F to 131 °F)
-30 °C to 70 °C (-22 °F to 158 °F)
4 kV (supply - output)
any
DIN rail EN 60715
IP40 from front panel / IP20 terminals
III.
2
solid wire max. 1x 2.5 or 2x 1.5 /
with sleeve max. 1x 2.5 (AWG 12)
90 x 17.6 x 64 mm (3.5˝ x 0.7˝ x 2.5˝)
75 g (2.6 oz.)
EN 61812-1, EN 61010-1
47 kΩ, linear
IP65 from front side / IP20 from back side
1.5 with sleeve / without sleeve max. 2.5 (AWG 12)
22 g (0.8 oz.)
27
B1 B3 B2
15
Function
Delay ON after energisation
a
U
t
t
Cycler beginning with pause after
energisation
c
U
t
t
t
t
t
t
Delay OFF after de-energisation, instant
make of output
e
S
t
t
Delay OFF after break of control contact
with instant output
g
S
t
t
Impulse relay
i
S
More accurate setting of timing for long periods of time
Example of time setting to 8 hours period:
For rough setting use time scale 1 - 10 s on the potentiomenter.
On the external potentiometer for fi ne adjustment of time to adjust 8 s, check accuracy
(eg. a stopwatch).
On rough time setting, set potentiometer to originally desired scale 1 - 10 hours, leave
a fi ne setting as it is.
Warning
Device is constructed for connection in 1-phase main alternating current and must be
installed according to norms valid in the state of application. Connection according to the
details in this direction. Installation, connection, setting and servicing should be installed
by qualifi ed electrician staff only, who has learnt these instruction and functions of the
device. This device contains protection against overvoltage peaks and disturbancies
in supply. For correct function of the protection of this device there must be suitable
protections of higher degree (A, B, C) installed in front of them. According to standards
elimination of disturbancies must be ensured. Before installation the main switch must
be in position "OFF" and the device should be de-energized. Don´t install the device to
sources of excessive electro-magnetic interference. By correct installation ensure ideal
air circulation so in case of permanent operation and higher ambient temperature the
maximal operating temperature of the device is not exceeded. For installation and
setting use screw-driver cca 2 mm. The device is fully-electronic - installation should be
carried out according to this fact. Non-problematic function depends also on the way of
transportation, storing and handling. In case of any signs of destruction, deformation,
non-function or missing part, don´t install and claim at your seller. After stop using the
product it is possible to demount and recycle.
2 / 2
Delay OFF after energisation
b
U
t
t
Cycler beginning with impulse after
energisation
d
U
t
t
t
t
t
t
Delay OFF responding to make of
control contact regardless its length
f
S
t
t
Delay OFF after make and break of
control contact
h
S
t
t
t
t
Pulse generator (puls = 0.5s)
j
U
t
PULS
t
PULS

Publicidad