SICK WL18-3 Manual De Operación página 3

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
3
COMMISSIONING
2
y
100
C 110
10
PL 30 A
Scanning
Diamond
range
Grade
max. typical
1
1
2
Image 1: H
2
Mount the sensor and the reflector using suitable mounting brackets (see the SICK
range of accessories). Align the sensor and reflector with each other.
Note the sensor's maximum permissible tightening torque of 1.3 Nm.
3
The sensors must be connected in a voltage-free state (U
in the graphics [B] must be observed, depending on the connection type:
Male connector connection: pin assignment
Cable: core color
Technical data and connection diagrams (figure B) starting on page 56.
Only apply voltage/switch on the power supply (U
tions have been established. The green LED indicator lights up on the sensor.
Explanations of the connection diagram (Graphic B):
Switching outputs Q and /Q (according to Graphic B):
WL(F)18-3P/K/V (PNP: load -> M)
WL(F)18-3N (NPN: load -> L+)
Alarm/health = diagnostic output (see Additional functions)
TI / Test = test input (see Additional functions)
4
Align the sensor with a suitable reflector. Select the position so that the red emit‐
ted light beam hits the center of the reflector. The sensor must have a clear view of
the reflector, with no object in the path of the beam [see E]. You must ensure that
the optical openings of the sensor and reflector are completely clear.
WL18-3
PL 80 A
Operating
range
3
4
5
6
7
x [m]
= 0 V). The information
v
> 0 V) once all electrical connec‐
v
8010585.YM42 | SICK
Subject to change without notice

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wlf18-3

Tabla de contenido