1

General safety notes

2

Notes on UL approval

3

Correct use

4

Commissioning

4.1

Check the application conditions

8016953.1ABM / 2020-12-21 | SICK
Subject to change without notice
Read the operating instructions before commissioning.
Connection, mounting, and configuration may only be performed by trained
specialists.
NO
2006/42/EC
Not a safety component in accordance with the EU Machinery Directive.
SAFETY
Do not install the sensor at locations that are exposed to direct sunlight
or other weather influences, unless this is expressly permitted in the operating
instructions.
These operating instructions contain information required during the life cycle of
the sensor.
UL: Only for use in applications in accordance with NFPA 79. These devices shall be
protected by a 1 A fuse suitable for 30 V DC.
Adapters listed by UL with connection cables are available.
Enclosure type 1.
The GRTE18 is an opto-electronic photoelectric proximity sensor (referred to as "sensor"
in the following) for the optical, non-contact detection of objects, animals, and persons.
If the product is used for any other purpose or modified in any way, any warranty claim
against SICK AG shall become void.
Energetic photoelectric proximity sensor
Check the application conditions: Adjust the sensing range and the remission capability
of the object according to the corresponding diagram [H] (x = sensing range, y =
operating reserve).
During this process, an object can only be detected in front of a background if the
remission capability of the object is significantly higher than that of the background or if
the distance between the object and the background is sufficiently long.