Setting; Troubleshooting; Troubleshooting Table - SICK GRL18V Instrucciones De Operación

Ocultar thumbs Ver también para GRL18V:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58
7.3

Setting

8

Troubleshooting

8.1

Troubleshooting table

8021183.1ABM / 2020-12-21 | SICK
Subject to change without notice
Figure 4: Sensing range
Table 3: Definition of sensing range
2
PL80A
1
PL40A
2
PL20A
3
P250
4
PL22
5
REF-Plus 3436
6
Sensitivity setting
Sensor which it is not possible to set: The sensor is adjusted and ready for operation.
The sensitivity is adjusted with the potentiometer (type: 270°). Clockwise rotation:
operating reserve increased; counterclockwise rotation: operating reserve reduced. We
recommend setting the potentiometer to "Maximum". A lower operating reserve may be
necessary for depolarizing surfaces.
The sensor is adjusted and ready for operation.
The Troubleshooting table indicates measures to be taken if the sensor stops working.
Table 4: Troubleshooting
LED indicator/fault pattern
Green LED does not light up
Green LED does not light up
Green LED does not light up
Yellow LED flashes
1
GRL18(S)V
0.03 ... 7.2 m
0.03 ... 6.2 m
0.03 ... 3.8 m
0.03 ... 6.4 m
0.03 ... 2.2 m
0.06 ... 2.0 m
Cause
No voltage or voltage below
the limit values
Voltage interruptions
Sensor is faulty
Sensor is still ready for oper‐
ation, but the operating condi‐
tions are not ideal
COMMISSIONING
2
Measures
Check the power supply,
check all electrical connec‐
tions (cables and plug connec‐
tions)
Ensure there is a stable power
supply without interruptions
If the power supply is OK,
replace the sensor
Check the operating condi‐
tions: Fully align the beam
of light (light spot) with the
reflector / Clean the optical
surfaces (sensor and reflec‐
tor) / Readjust the sensitiv‐
ity (potentiometer) / If the
potentiometer is set to the
7
9

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Grl18sv

Tabla de contenido