Figure 11
The duty cycle percentage is referred to the low level portion of the PWM signal
NOTE
Programmable analog signal: this output signal is a voltage (from 0
to 10 Vdc) proportional to a reference quantity (frequency or power)
set by the user. The default setting is the frequency (see the following
example diagram).
Figure 12
Turbo-V 1K-G Retrofit User Manual / 87-900-996-01 (B)
Interconnections – Controller Model 9698978M004
amplitude: 24 V max
duty cycle range: from 25% to 75%
corresponding to an output frequency from 500 Hz to 761 Hz (see
the following diagram).
Technical Information
251/294