Malfunction
No fastener is driven.
No fastener is driven
(or driven only intermit-
tently).
A fastener cannot be re-
moved from the fastener
guide.
14
Possible cause
Nail transport malfunction.
The battery is discharged.
Empty gas can
LED 1 lights red
Incorrect piston position
due to lifting the tool away
too soon after driving the
fastener.
Incorrect piston position due
to carbon build-up.
The tool doesn't fire due to a
dirty spark plug.
Foreign object in the area of
the fastener guide.
Electronic fault.
Ambient conditions are out-
side the permissible range.
The gas can temperature
is outside the permissible
range.
The tool was not lifted com-
pletely away from the sur-
face after driving a fastener.
A fastener has jammed in
the fastener guide.
Action to be taken
▶ Check the nail strip and, if
damaged, use a new one.
▶ Clean the magazine and
the fastener guide.
▶ Change the battery.
▶ Check the status of the
gas can. → page 9
▶ Check the status of the
gas can. → page 9
▶ Keep the tool pressed
against the surface for
longer.
▶ Clean the fastening tool
→ page 11.
▶ Clean the fastening tool.
→ page 11
▶ Remove foreign objects
from the area of the
fastener guide. → page 11
▶ Remove the gas can and
then reinsert it. If the
problem persists, use a
new gas can.
▶ Remove the battery and
then reinsert it.
▶ Make sure that the per-
missible ranges, in accor-
dance with the technical
data, are observed.
▶ Make sure that the per-
missible ranges, in accor-
dance with the technical
data, are observed.
▶ Lift the fastening tool
completely away from
the working surface after
driving a fastener.
▶ Remove the fastener
guide → page 10.
▶ Release the jammed
fastener.
▶ Clean the fastener guide.
▶ Remove foreign objects
from the area of the
fastener guide.