When adding objects to the pan, be sure that the
quantity is LESS THAN those already on the platform.
An alarm will sound a beep when the unit weight is
averaged again.
LACK OF UNIT WEIGHT
If the unit weight is no more than 4/5 of the set display
resolution (accuracy) or less than a 10 piece sample,
the sample insufficient light will blink in the lower-right
corner of the UNIT WEIGHT display, reminding the user
that the unit weight is too small for accurate quantity
calculations.
MINIMUM PIECE
MODEL
H-1121
H-1122
H-1123
If the unit weight is too light, another scale is needed.
Continuing to use this scale will result in less accurate results.
TARE
When weighing an item that is in a container, taring
stores the container weight to memory.
To store the tare weight into memory and set the WEIGHT
display as zero:
1.
Place an empty container on the platform.
2. Press TARE. The word TARE will be displayed in the
lower left of the WEIGHT display.
The container's weight is then stored in the scale's
memory.
3. Add pieces to the container. As the pieces are
added, their net weight will be displayed.
Removing the container from the platform will cause the
scale to display the container's weight as a negative
number. Pressing the TARE or ZERO key will readjust the
scale to zero.

CHECK COUNTING

Users can set a number for counting check. When the
number of objects on the platform is equal to or larger
than the preset checking number, the alarm sound
beeps repeatedly.
SET CHECK COUNT
1.
Press CK key. CH will blink in the WEIGHT display and
the Hi setting will be shown in the UNIT WEIGHT display.
2. Key in the desired checking number.
3. Press the • key to switch to Lo setting.
PAGE 4 OF 18
OPERATION CONTINUED
MINIMUM
WEIGHT
SAMPLE WEIGHT
.0005 lbs.
.020 lbs.
0.001 lbs.
.040 lbs.
0.002 lbs.
.080 lbs.
4. Key in the desired number.
5. Press CK again to accept.
CLEAR CHECK COUNT
1.
Press the CK key.
2. Press the • key twice to reset.
ACCUMULATION
Use the M+, MR and MC keys to add, recall or clear
weight, accumulation times and total count.
ACCUMULATE DATA
Press the M+ key after the weight and total count has
been calculated and displayed. M+ will light up.
The scale will show the accumulated weight in the
WEIGHT display, "ALL XX" (or ALL X) in the UNIT WEIGHT
display (XX represents the total accumulation times; at
the most 99 accumulations can be accepted), and the
total quantity in the TOTAL COUNT display.
ADDING ADDITIONAL LOTS
Remove the current lot of objects from the platform.
Put on the next lot of objects and press the M+ key
again. New data will then be added to the memory.
RECALL DATA
Stored data can be recalled by pressing the MR
key. When this is pressed, the scale will show the
accumulated data. Total weight will be shown in the
WEIGHT display and the total quantity will be shown in
the TOTAL COUNT display.
The UNIT WEIGHT display will show ALL XX (or ALL X). XX
represents the total accumulated times.
Press MR repeatedly and the scale will show the stored
data from item 1 to the last item (at most, 9 individual
items will be displayed). The UNIT WEIGHT display will
show ACC XX or ACC X to indicate the number of the
displayed item.
All the recalled data will be displayed in revolving order
if MR is pressed repeatedly.
CLEAR DATA
Press the MC key to clear the stored data. When MC is
pressed in the normal weighing mode, or in the memory
recall mode with accumulated data displayed (the UNIT
WEIGHT display shows ALL XX), the UNIT WEIGHT display
will show ALL 0, and both the accumulated data and the
individual item will be cleared.
If MC is pressed in the memory recall mode, when the
individual item is displayed (the UNIT WEIGHT display
shows ACC XX), only the displayed individual item will
be cleared.